Subscribe to our Newsletter
Model No: LHG10K~12K-P3LV-EU
10KW-12KW 3P LV Hybrid Inverter
Quantity :
DATA SHEET
Elevate Your Energy. Solenux
ModelLHG10K-P3LV-EU / LHG12K-P3LV-EU
| PV String Input Data | ||
|---|---|---|
| Max. PV Access / Max. PV Input Power (W) | 20000/13000 | 24000/15600 |
| Rated PV Input Voltage (V) | 550 (160-800) | |
| Start-up Voltage (V) | 160 | |
| MPPT Voltage Range (V) | 200-650 | |
| Full Load MPPT Voltage Range (V) | 350-650 | |
| Max. DC Input Current (A) | 26+13 | |
| Max. DC Short Circuit Current (A) | 34+17 | |
| No. of MPPT Trackers | 2 | |
| No. of Strings Per MPPT Tracker | 2+1 | |
| AC Input/Output Data | ||
| Rated AC Output and UPS Power (W) | 10000 | 12000 |
| Max. AC Output Power (W) | 11000 | 13200 |
| AC Output Rated Current (A) | 16.7 | 18.2 |
| Max. AC Output Current (A) | 18.4 | 20 |
| Max. Output short circuit current (A) | 75 | |
| Max. Continuous AC Passthrough (A) | 45 | |
| Peak Power (off grid) | 2 times of rated power, 10S | |
| Power Factor | 0.8 leading to 0.8 lagging | |
| Output Frequency and Voltage | 50/60Hz; 3L/N/PE 220/380Vac, 230/400Vac | |
| Grid Type | Three Phase | |
| Total Harmonic Distortion (THDi) | <3% (of nominal power) | |
| DC current injection | <0.5% ln | |
| Battery Input Data | ||
| Battery Type | Lead-acid or Lithium-ion | |
| Battery Voltage Range (V) | 40-60 | |
| Max. Charging Current (A) | 200 | 240 |
| Max. Discharging Current (A) | 200 | 240 |
| External Temperature Sensor | Yes | |
| Charging Curve | 3 Stages/Equalization | |
| Charging Strategy for Li-Ion Battery | Self-adaption to BMS | |
| Efficiency | ||
| Max. Efficiency | 97.6% | |
| Euro Efficiency | 97.0% | |
| MPPT Efficiency | 99.0% | |
| Protection | ||
| Anti-islanding Protection | Yes | |
| PV String Input Reverse Polarity | Yes | |
| Insulation Resistor Detection | Yes | |
| Residual Current Monitoring Unit | Yes | |
| Output Over Current Protection | Yes | |
| Output Shorted Protection | Yes | |
| Output overvoltage protection | Yes | |
| Photovoltaic input lightning | Yes | |
| Surge Protection | DC Type III/AC Type III | |
| Over Voltage Category | DC Type II/AC Type III | |
| Certifications and Standards | ||
| Grid Regulation | IEC61727/62116, EN50549-1 | |
| EMC/Safety Regulation | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |
| General Data | ||
| Operating Temperature Range (℃) | -40-60℃, >45℃ Derating | |
| Cooling | Smart Cooling | |
| Noise (dB) | ≤50 dB | |
| Communication with BMS | RS485; CAN | |
| Monitoring Mode | Wi-Fi+APP | |
| Weight (kg) | 37.5 | |
| Size (W x H x D mm) | 702×422×281 (Excluding Connectors and Brackets) | |
| Ingress Protection | IP65 | |
| Installation Style | Wall-mounted | |
| Warranty | 5 Years (10 Years Optional) | |