Elevate Your Energy

0
Model No: LHG15K~20K-P3LV-EU

15KW-20KW 3P LV Hybrid Inverter

Quantity :
add to cart
Contact Now

DATA SHEET

Elevate Your Energy. Solenux

ModelLHG15K-P3LV-EU / LHG18K-P3LV-EU / LHG20K-P3LV-EU
Battery Input Data
Battery TypeLead-acid or Lithium-ion
Battery Voltage Range (V)40-60
Max. Charging Current (A)280330350
Max. Discharging Current (A)280330350
Charging Strategy for Li-Ion BatterySelf-adaption to BMS
Number of Battery Input2
PV String Input Data
Max. PV Access / Max. PV Input Power (W)30000/2400036000/2880040000/32000
Max. DC Input Voltage (V)800
Start-up Voltage (V)160
PV Input Current (A)160-800
MPPT Voltage Range (V)160-650
Full Load MPPT Voltage Range (V)330-650400-650440-650
Rated PV Input Voltage (V)550
Max. Operating PV Input Current (A)36+36
Max. Input Short-Circuit Current (A)54+54
No. of MPP Trackers / No. of Strings MPP Tracker2/2+2
Max. Inverter Backfeed Current to The Array0
AC Input/Output Data
Rated AC Input/Output Active Power (W)150001800020000
Max. AC Input/Output Apparent Power (VA)165001980022000
Peak Power (off grid) (W)2 times of rated power, 10s
Rated AC Input/Output Current (A)22.8/21.827.3/26.130.4/29
Max. Rated AC Input/Output Current (A)25/2430/28.733.4/31.9
Max. Continuous AC Passthrough (grid to load) (A)70
Max. Output Fault Current (A)506066.8
Max. Output Overcurrent Protection (A)100
Rated Input/Output Voltage/Range (V)220/380V, 230/400V 0.85Un-1.1Un
Grid Connection Form3L+N+PE
Rated Input Grid Frequency/Range50Hz/45Hz-55Hz 60Hz/55Hz-65Hz
Power Factor Adjustment Range0.8 leading-0.8 lagging
Total Harmonic Distortion (THDi)<3% (of nominal power)
DC Injection Current<0.5% In
Efficiency
Max. Efficiency97.6%
Euro Efficiency97.0%
MPPT Efficiency>99.0%
Protection
DC Polarity Reverse Connection ProtectionYes
AC Output Overcurrent ProtectionYes
AC Output Overvoltage ProtectionYes
AC Output Short Circuit ProtectionYes
Thermal ProtectionYes
DC Terminal Insulation Impedance MonitoringYes
DC Component MonitoringYes
Ground Fault Current MonitoringYes
Arc fault circuit interrupter (AFCI)Optional
Power Network MonitoringYes
Island Protection MonitoringYes
Earth Fault DetectionYes
DC Input SwitchYes
Overvoltage Load Drop ProtectionYes
Residual Current (RCD) DetectionYes
Surge Protection LevelType II (DC) / Type II (AC)
Interface
DisplayLCD+LED
Communication InterfaceRS232, RS485, CAN
Monitor ModeGPRS/WIFI/Bluetooth/4G/LAN (optional)
General Data
Operating Temperature Range (℃)-40 to +60℃, >45℃ Derating
Permissible Ambient Humidity0-100%
Permissible Altitude3000m
Noise (dB)<60 dB
Ingress Protection (IP) RatingIP66
Inverter TopologyNon-Isolated
Over Voltage CategoryOVC II (DC), OVC III (AC)
Weight (kg)52
Cabinet size (mm) (W×H×D)435×750×268
Warranty5 Years/10 Years (the Warranty Period Depends the Final Installation Site of Inverter)
Type of CoolingIntelligent Air Cooling
Grid RegulationIEC 61727, IEC 62116, EN 50549
Safety EMC/StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2