Subscribe to our Newsletter
Model No: LHG80K-P3HV-EU
80KW 3P HV Hybrid Inverter
Quantity :
DATA SHEET
Elevate Your Energy. Solenux
ModelLHG80K-P3HV-EU
| Battery Input Data | |
|---|---|
| Battery Type | Lithium-ion |
| Battery Voltage Range (V) | 160-1000 |
| Max. Charging Current (A) | 80+80 |
| Max. Discharging Current (A) | 80+80 |
| Charging Strategy for Li-Ion Battery | Self-adaption to BMS |
| Number of Battery Input | 2 |
| PV String Input Data | |
| Max. PV Access Power (W) | 160000 |
| Max. PV Input Power (W) | 128000 |
| Max. PV Input Voltage (V) | 1000 |
| Start-up Voltage (V) | 180 |
| PV Input Voltage Range (V) | 180-1000 |
| MPPT Voltage Range (V) | 180-850 |
| Full Load MPPT Voltage Range (V) | 485-850 |
| Rated PV Input Voltage (V) | 650 |
| Max. Operating PV Input Current (A) | 36+36+36+36+36+36 |
| Max. Input Short-Circuit Current (A) | 54+54+54+54+54+54 |
| No. of MPP Trackers / No. of Strings MPP Tracker | 6/2+2+2+2+2+2 |
| Max. Inverter Backfeed Current to The Array | 0 |
| AC Input Data | |
| Rated AC Input/Output Active Power (W) | 80000 |
| Max. AC Input/Output Apparent | 88000 |
| Peak Power (off grid) (W) | 1.5 times of rated power, 10s |
| Rated AC Input/Output Current (A) | 121.3/116 |
| Max. Rated AC Input/Output Current (A) | 133.4/127.6 |
| Max. Continuous AC Passthrough (grid to load) (A) | 200 |
| Max. Output Fault Current (A) | 256 |
| Max. Output Overcurrent Protection (A) | 334 |
| Rated Input/Output Voltage/Range (V) | 220/380V, 230/400V 0.85Un-1.1Un |
| Grid Connection Form | 3L+N+PE |
| Rated Input Grid Frequency/Range | 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz |
| Power Factor Adjustment Range | 0.8 leading-0.8 lagging |
| Total Harmonic Distortion (THDi) | <3% (of nominal power) |
| DC Injection Current | <0.5% In |
| Efficiency | |
| Max. Efficiency | 98.7% |
| Euro Efficiency | 98.1% |
| MPPT Efficiency | >99.0% |
| Equipment Protection | |
| DC Polarity Reverse Connection Protection | Yes |
| AC Output Overcurrent Protection | Yes |
| AC Output Overvoltage Protection | Yes |
| AC Output Short Circuit Protection | Yes |
| Thermal Protection | Yes |
| DC Terminal Insulation Impedance Monitoring | Yes |
| DC Component Monitoring | Yes |
| Ground Fault Current Monitoring | Yes |
| Arc fault circuit interrupter (AFCI) | No |
| Power Network Monitoring | Yes |
| Island Protection Monitoring | Yes |
| Earth Fault Detection | Yes |
| DC Input Switch | Yes |
| Overvoltage Load Drop Protection | Yes |
| Residual Current (RCD) Detection | Yes |
| Surge Protection Level | Type III (DC) / Type III (AC) |
| Interface | |
| Display | LCD+LED |
| Communication Interface | RS232, RS485, CAN |
| Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN (optional) |
| General Data | |
| Operating Temperature Range | -40 to +60℃, >45℃ Derating |
| Permissible Ambient Humidity | 0-100% |
| Permissible Altitude | 3000m |
| Noise (dB) | ≤65 dB |
| Ingress Protection (IP) Rating | IP66 |
| Inverter Topology | Non-Isolated |
| Over Voltage Category | OVC II (DC), OVC III (AC) |
| Weight (kg) | 105 |
| Cabinet size (mm) (W×H×D) | 570×925×333 (Excluding connectors and brackets) |
| Installation Style | Wall-mounted |
| Warranty | 5 Years/10 Years |
| Type of Cooling | Smart cooling |
| Grid Regulation | IEC 61727, IEC 62116, EN 50549 |
| Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |